Products
PRODUCT CENTER
On-line Monitoring System of Transformer Core Grounding Current
Category: Product Center
Key words: equipment
Product Description
2.1.2 Product model and technical parameters
| Picture | Functional features | |
|
Core/Clamp Monitoring Device |
LHTX1306B-C:485 signal LHTX1306B-I:4-20mA signal Size: 160*180 *167mm optional: In-Place Display |
1. High-precision zero-flux transformer, through-core monitoring mode. The original wiring mode shall not be changed; 2, real-time monitoring and collection of iron core/clamp grounding current and analysis, local display, data remote transmission and processing; 3. OLED local display function: time, date, current value, alarm value; 4. Setting function: time, current alarm threshold, communication address; 5. Storage function: current real-time data; 6. Communication function: RS485 (convenient networking),4-20mA, DL/T860 (IED required); 7. Measurement range: 1mA ~ 30A resolution 0.1mA; 8. Measurement accuracy: ± (standard reading * 1 mA); 9. Alarm threshold: default 100mA; 10. Dry contact output: capacity AC220V/3A; 11. Working environment:-40 ℃ ~ 65 ℃; 12. Working environment humidity: ≤ 90%; 13. Storage and transportation temperature:-25 ℃ ~ 85 ℃; 14. Protection grade: IP66 altitude:<4000 m. |
| Core/Clamp Monitoring Device (Offshore Wind Power Only) |
LHTX1306B-CH1:485 signal/4-20mA signal size: 206*277*200mm
|
1. High-precision zero-flux transformer, through-core monitoring mode. The original wiring mode shall not be changed; 2, real-time monitoring and collection of iron core/clamp grounding current and analysis, data remote transmission and processing; 3. Setting function: time, current alarm threshold, communication address; 4. Storage function: current real-time data; 5. Communication function: RS485 (convenient for networking), 4-20mA, DL/T860 (IED required); 6. Measurement range: 1mA ~ 30A resolution 0.1mA; 7. Measurement accuracy: ± (standard reading * 1 mA); 8. Alarm threshold: default 100mA; 9. Dry contact output: capacity AC220V/3A; 10. Working environment:-40 ℃ ~ 65 ℃; 11. Working environment humidity: ≤ 90%; 12. Storage and transportation temperature:-25 ℃ ~ 85 ℃; 13. Protection grade: IP66 anti-salt spray grade: C5-M. |
|
Core/Clamp Monitoring IED |
LHTX1306B-IED standard 2U chassis (local display) rulerInch:482.5*88.5*256mm |
1, support modbus communication protocol, 61850 (DL/T860)Communication protocol (optional); 2. Simultaneous displayMultiple sets of transformer core and clamp current; 3. OLED scrolling display; 4. Upload the data to the background monitoring center in real time. |
* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.